⚡ POWER ENGINEERING - MADE OBVIOUS

Design power systems with confidence.

VoltWorks turns a blank page into a checked, documented power design: size feeders, transformers and cables, check fault levels and arc-flash PPE, draw the single-line diagram, and walk the substation in 3D. Everything runs in your browser, no sign-up, no uploads, nothing to break.

11power modules
11guided tours
100%client-side
1Enter your numbers: plain labels, worked examples, no jargon.
2Read the verdict: green means go, red tells you exactly what to fix.
3Export the report: one document, ready to print or file.
Not sure where to start? Pick your job:
Built on IEC 60364 · IEC 60909 · IEEE 1584-2018 · NFPA 70E · IEC 60076 · IEEE C57 · AS/NZS 3000 This is a design aid: results must be verified by a licensed engineer before construction or procurement.
👋 New here? Each section has a “How this works” panel with a plain-English explanation and a one-click worked example.
01

Power Systems

Per-unit base, feeder voltage drop, transformer sizing, LV cable sizing and transformer-bus fault level, ported from PowerSys Pro + psextract.

◈System Base

Per-unit reference shared by fault calculations below.

〜Feeder Voltage Drop

3-phase feeder drop from R/X per km, length, load and PF.

▣Transformer Sizing + Fault Level

Recommended standard size, utilisation and symmetrical/asymmetrical fault current.

🔌LV Cable Sizing IEC 60364

Copper XLPE, derated for installation + ambient, with VD check.

⚠Short-Circuit at Bus

Fault current at transformer LV bus including feeder impedance.

📏Design Standards

Switches formulas, limits and references across the calculators.

📈Live Load Study 0–150%

Drag the slider: feeder VD, transformer loading and cable VD recalculate live from your inputs above. Same slider drives SLD loading colours.

100%
02

Power Flow (Load Flow)

Newton–Raphson AC load flow on a user-editable network. Edit bus loads/generation and branch impedances, then solve: bus voltages, angles, branch flows and losses are computed, not mocked. Bus type: slack (1, reference), PV (generator, holds V), PQ (load).

Buses - edit V (kV), Type, P (kW), Q (kVar); Vm/angle are solved

#NameV kVTypeP kWQ kVarVm p.u.Va °

Branches - R, X in Ω, rating kVA

FromToR ΩX ΩRate kVAP→ kWQ→ kVarLoad %Loss kW
Ready: press Solve load flow.
03

Motor Starting: Voltage Dip

Locked-rotor inrush and the voltage dip it imposes at the point of common coupling (PCC). Impedance-divider method per IEC 60034-12 / AS-NZS 3000 §3.5. Checks against typical start-dip limits.

ⓂMotor + Supply

Motor nameplate + upstream fault level at the PCC.

📉Start Method Comparison

Same motor started four ways: effective inrush and resulting PCC dip.

MethodI_start ADip %Status
04

Cable Short-Circuit Withstand

Adiabatic thermal check (IEC 60364-4-43 / BS 7671): a conductor must survive fault energy I²t without exceeding its insulation temperature. Computes minimum area and maximum permissible clearing time.

🔥Adiabatic Check k²S² ≥ I²t

k from material + insulation (BS 7671 Table 43.1).

📋k Factors

Typical conductor k (BS 7671 Table 43.1), for ≤5 s faults.

InsulationCuAl
XLPE / EPR (90°C)14394
PVC (70°C)11576
PVC (90°C)10066
Bare conductor176116
05

Power Factor Correction

Size a capacitor bank to raise power factor to a target: Q_c = P·(tan φ₁ − tan φ₂). Includes detuning note for harmonic-rich systems.

⚙Capacitor Sizing

Existing load + present/target power factor.

📊What changes

Before vs after correction.

QuantityBeforeAfter
06

Arc Flash Hazard IEEE 1584-2018

Incident energy and arc-flash boundary per the IEEE 1584-2018 empirical model (1,800+ tests): arcing current (with reduced-current case), enclosure size correction, and PPE category per NFPA 70E. Safety-critical: verify against your protection study before use.

⚡Arc Flash Calculation

Equipment + fault data. Voltage 208 V–15 kV; G per equipment class.

🦺PPE Category NFPA 70E

PPE category from the highest (reduced-current) incident energy.

CaseI_arc kAE cal/cm²AFB mmPPE
PPE CatIncident energy
0 / none≤ 1.2 cal/cm²
1≤ 4
2≤ 8
3≤ 25
4≤ 40
07

Network Analysis Report

psextract-style system report. Edit bus voltages live: compliance re-evaluates instantly. Sample 5-bus demo case preloaded.

Bus Results - click Vm / load cells to edit

BusNameV (kV)Vm (p.u.)Va (°)P (kW)Q (kVar)Status

Branch Power Flows

FromToPf (kW)Qf (kVar)Loading %Status

Short-Circuit Analysis (Z-bus method, sample)

BusI_sc (kA)S_sc (MVA)Z_sc (Ω)Breaker ≥

NERC Compliance

CheckResultStatus

Generator Dispatch

UnitP (kW)Q (kVar)Vset (p.u.)Profile
08

Single-Line Diagram Builder

Click a component on the left to drop it on the canvas: there are no modes to learn. The new symbol is placed for you and, if something is already selected, wired to it automatically, so you can build a feeder by simply clicking Generator → Breaker → Busbar → Transformer → Motor. To connect two things by hand, drag a ● dot onto another symbol: it snaps for you, so you don't need to aim precisely. The canvas is unlimited: pan with Space-drag or middle-drag and zoom out freely, and the grid follows you. Drag a symbol to move it (it snaps to the grid and shows alignment guides against its neighbours), click a breaker to open or close it, double-click a load to change its loading.

Components

Click to add · or drag onto the canvas

Start from a template

Start over

🗺 Draw your single-line diagram

Click a component on the left to drop it here, or start from a ready-made template.

Click a component to add · drag a ● dot to connect (it snaps) · wheel = zoom · ✋ Pan / Space / middle / right-drag = move the plane · arrows = nudge · Del = delete
0 components · 0 connections

Properties

Select an element to edit its properties.
09

3D Substation Viewer

The whole substation in 3D: what every tool in this app is actually describing. Grid infeed → gantry → breaker → 11 kV bus → transformer → LV switchgear → capacitor bank → motor + loads, with live loading colours, power-flow particles and the arc-flash zone around the switchgear. Switch the source to SLD diagram and the same viewer rebuilds itself from whatever you drew in the SLD Builder.

Source Focus
View
3D could not load (Three.js CDN blocked). All calculators and the 2D SLD still work: check your connection and press Re-sync.
≤ 80% loaded80–100%> 100% / open / arc zoneDe-energised● Flow dots move from source → load; faster = heavier loading.

True scale for design review: 1 unit = 1 metre, equipment heights match real dimensions (11 kV pylon 12 m · transformer ≈ 2.5 m · worker 1.8 m). Positions are illustrative, not construction drawings. Drag to orbit · scroll to zoom · right-drag to pan · click any equipment for its details.

10

Substation Map

Live power infrastructure on OpenStreetMap data: transmission and distribution lines coloured by voltage from OpenInfraMap, with substations loaded live from Overpass as you pan and zoom. Zoom in to level 11 or closer to load live substation markers for the area on screen.

Map loads when this section scrolls into view. Zoom in to load live substation data.

Voltage unknown up to 10 kV up to 25 kV up to 52 kV up to 132 kV up to 220 kV up to 310 kV 550 kV and above Underground cable Substation (vector layer) Live substation (Overpass)
11

Engineering Report

Collects your latest results from every module above into one professional report. Print or save as PDF.